Feature

Pre-vacuum and post vacuum Drying system
Pre-vacuum for effective air removal that results in increasing sterilization performance.
Post-vacuum for drying with remaining system removal

Microprocessor PID program controller with self auto-tuned and LCD display
3 pre-programmed (wrapped, unwrapped, liquid course) and 1 Bowie-dick test and 1 user manual mode

Full automatic operation system with working process cycle LED indicator
Easy operation with full automatic cycle by micro processor, from beginning to end cycle

Sterilization temperature 110°C to 135°C EN-13060-2 /EN -285 class B sterilization
Pre-vacuum-water filling-heating-sterilizing-ventilation-post vacuum drying-end cycle

Self-diagnostic and safety system

In case of any malfunction, it alarms and displays error codes for easy maintenance, being stop working with automatic ventilation process for safety

Optional Accesories
Class B Sterilization cycle












Patent Pending State of the art Technology 

MODEL
LAC-5045SP
LAC-5065SP
LAC-5085SP
LAC5105SP
Sterilization Class B
Built-in pre-vacuum system & post vacuum drying system
Dimensions                     Outer
(W x D x H mm)           Inner
770x560x900
Ø350x240
770x560x1000
Ø350x630
860x650x950
Ø450x500
860x650x1100
Ø450x630
Capacity
40ℓ
60ℓ
80ℓ
100ℓ
Reservoir Capacity
10 ℓ
12 ℓ
14 ℓ
16 ℓ
Material                    Exterior
                                 Chamber
Heavy-Duty Epoxy Resin powder coated EGI steel
Stainless steel 304 (STS 316 L option)
Heater
3kW + (Dry 1kW)*
3kW + (Dry 1kW)*
5kW + (Dry 1kW)*
5kW + (Dry 1kW)*
Sterilization Temperature
110°C - 135°C (Max)
Pressure Range
0.4 – 2.3kgf/cm²
Dry System
Post vacuum to remove steam vapor / 0-60 min
Vacuum/Pressure Gauge
-0.1 ~ 0.4Mpa (760mmHg – 4kgf/cm2)
Controller
Microprocessor PID Program Controller with LCD Monitor
Operation Cycle Mode
3 Programmed cycle, 1 Bowie-Dick test, 1 User men
Pre & Post Vacuum System
Diaphragm vacuum pump 50 LPM capacity
Display
LCD monitor (Temperature, Timer, Program cycle)
LED indicator (Water, Heat, Sterilization, Dry, End cycle)
Timer
4-90 min Sterilization & 1-90 min Dry time
PC Communication
RS-232C interface (Option)
Door
Heavy Duty Hinged up & down door
Safety Device
Over pressure safety valve, Over temperature / Overheating and over temperature protector
Door open sensing & power cut – off, Low water prevention device / Leakage & Over current circuit breaker
Standard Basket
2 ea of stainless wire basket included
Electric supply
110V, 60Hz or 220V, 50/60Hz
*separate heater ( ) for drying process

MODEL
LAC-5042SE
LAC-5062SE
LAC-5082SE
LAC-5102SE
Sterilization Class N
Without pre-vacuum & without post vacuum drying system