Steam Sterilizer

Steam Sterilizer
















Feature

Sterilization temperature 110°C to 135°C En-13060-2 class B sterilization cycle
Pre vacuum-water filling-heating-sterilizing-ventilation-post vacuum drying-end cycle

Pre vacuum air removal and Post vacuum Drying system
Pre-vacuum for effective air removal that result in increasing sterilization performance. Post-vacuum for drying with remaining steam removal.

Microprocessor program controller with self auto-tuned and LCD monitor
7 pre-programmed cycle as 2 wrapped, 2 unwrapped liquid, Bowie-dick and 1 user programmable course

Full automatic operation system
Easy operation with full automatic process cycle by microprocessor controller from beginning to end cycle




Self – diagnostic and Safety system
In case of any malfunction, it alarms and displays error codes for easy maintenance, being stop working with automatic ventilation process for safety purpose

Air filtration cooling system
For the process of drying cycle, 0.2µm HEPA filtered clean air flows into the chamber in order to protect air contamination and to cool down below 60°C

Safe and Efficient water supply system
Automatic water supply mechanism which supplies a fixed volume of water to the chamber for maximum efficiency

Automatic and manual door lock system
When the sliding handle is entered into the locking ring, the door automatically locks after two second. The door can be manually opened and locked using the locking wheel system

Space saving compact design
Maximize working capacity with square chamber and minimize foot space with dedicated engineering design.



Safety Mechanism


-     Over pressure release valve
-     Over temperature protector with Thermostat
-     Higher temp set protector by Digital high alarm limit
-     Visible and Audible alarm system
-     Automatic dual door locking system

  











Programmed Sterilization Cycle
MODEL
Temperature (°C)
Pressure (kgf / cm2)
Sterilizing Time (min)
Drying Time (min)
Unwrapped 1
121
1.1
20
30
Unwrapped 2
134
2.1
5
30
Wrapped 1
121
1.1
30
30
Wrapped 2
134
2.1
15
30
Liquid
121
1.1
20
0
Bowie Dick
134
2.1
4
5-10
User Program
100-135
0.1-2.3
4-30
0-60
Class B Sterilization Cycle
 

Optional Accessories
Printer


Perforated Tray


Wire Tray

MODEL
LAC-1011SV
LAC-1021SV
LAC-1031SV
Dimensions        Inner
(W x D x H mm)      Outer
410 x 560 x 460
200 x 300 x 200
490 x 655 x 460
270 x 405 x 230
510 x 690 x 545
300 x 455 x 300
Capacity
12
25
40
Heater
2kW
2.5kW
2.5Kw
Chamber Type
Reinforced and electro polished square chamber
Material
Stainless Steel 304 standard (STS 316 L option)
Door lock mechanism
Automatic wheel inter locking with one touch sliding handle
Vacuum Pump
Built-in diaphragm vacuum pump 25 LPM capacity
Controller
Microprocessor Program Controller with LCD Monitor
Sterilization   Temp Range
                 Pressure Range                        .                            Course
110°C ~ 135°C
0.4 ~ 2.3kgf/cm2
Unwrapped 1&2 / Wrapped 1&2 / Liquid / Bowie-Dick / User program mode
Reservior
6 stainless steel tank with top wazer filling inlet and silicon closer
Safety
Over pressure release valve, Over temperature protector,
Visible and Audible alarm system, Automatic dual door locking system
Tray

180 x 260 mm
250 x 360 mm
290 x 400 mm
Perforated tray (Standard) / Wire tray (Option)
Electric Supply
110V 60Hz or 220V 50/60Hz

Related product you might see:

Share this product :

Post a Comment

 